Cathodic Protection

Steel can be protected by cathodic protection if it has been submerged in the electrolyte (water, soil, concrete) and if the surface of the steel and volume of the electrolyte are significant. Often this is combined with coatings, such as for ships and buried pipelines. But for example offshore platforms and offshore windmills are successfully protected uncoated for >30 years without any sign of corrosion.

For electrochemistry, cathodic protection performance easily can be measured with the SensCorr by connecting the working electrode to the object under protection. This is done via the enclosure through a cable from this object to the enclosure. In this way the rest potential Ecp is measured between the working electrode and the reference electrode (both made of carbon steel). Normally Ecp is -300 – -500 mV St..

After, the object is disconnected from the working electrode and the current belonging to Ecp is measured. This is the CP current density in mA/cm2. See the graph below with a lpr scan of the working electrode ‘under cathodic protection’. This current, knowing the surface of the electrode, is the current density of the CP system. The current density is very much depending on the formation of a complex (protective) calcareous layer and biofouling on the steel surface.

For years the CP performance and AC interference of buried pipelines is measured with ER probes. The SensCorr measures ER with a sensitivity of 0,1 micrometer metal loss.

Three parameters are logged:

  1. ER metal los in micrometer.
  2. The CP potential compared to the steel reference electrode in mV.
  3. The CP current density in mA/cm2.
Corroium_SencsCorr_Probe_900
Senscorr_Corrodium_Polarisation_curve
Senscorr_Pipeline_Corrodium_900